Skip to main content

TAC Security · Eregis ServiceBridge

ioXt

Prepare for ioXt assessment with product mapping, firmware remediation and evidence for the agreed route

Map ioXt program requirements to your product, profile and firmware version. Coordinate scoped firmware/configuration remediation and collect lab evidence for authorized ioXt lab review. Distinguish implementation preparation from the ioXt Alliance certification decision.

TAC assessment and Eregis implementation support are separate services. Credits fund scoped agent work; specialist support is quoted separately.

What you can expect to receive

ioXt requirement-to-product map

Structured mapping of each ioXt requirement to firmware/configuration locations, evidence status, and remediation priority per product profile and firmware version

Firmware and configuration evidence

Exported firmware builds, configuration manifests, and test results with ioXt requirement correlation and freshness timestamps

Tested firmware/configuration changes

Commits/PRs with validation tests, each linked to specific ioXt requirement IDs, product profile, and firmware version

Assessment evidence bundle

Requirement map, firmware evidence, remediation summaries and applicable submission checklist for the agreed testing route; lab-specific material where selected.

What to prepare and who does what

You approve the scope and authorize access. Cortex One and vetted specialists can implement changes within their assigned scopes. The assessor or independent reviewer decides the assessment outcome.

Repository write access and Development/Test environment write access are required only where the agreed remediation changes firmware/configuration or validates those changes. Requirement mapping and evidence preparation may use agreed evidence/read access. Lab access and test hardware are agreed separately with the authorized ioXt lab. Actual grants for targets and changes remain mandatory when those operations are selected; this does not imply unrestricted access.

  • Defined ioXt product and profile (required) · Product with its recorded ioXt profile, firmware version, and applicable specification version. The program version is project-specific and not an automatic change to an existing engagement's agreed version.
  • Applicable program and testing requirements (required) · Current ioXt criteria for the product profile and agreed testing route, including authorized-lab requirements where that route is selected.
  • Repository access authority · Authority to grant scoped read/write access to repositories containing firmware source code and configuration. Required only where agreed remediation changes firmware or validates those changes; requirement mapping and evidence preparation may use agreed evidence/read access.
  • Device specifications and test hardware access · Device specifications, test hardware, and lab access as agreed with the authorized ioXt lab

Delivery milestones

The planned steps and who is responsible for each one.

  1. Confirm ioXt scope

    Responsible Customer

    Confirm the ioXt program, product profile, firmware/specification version and applicable testing route: self-certification or authorized-lab testing. Supply the relevant program criteria and any selected lab requirements.

  2. Authorize repository and device access

    Responsible Customer

    Grant only the repository/device access needed for the agreed assistance, with separate expiring agent and professional grants. Lab access and hardware arrangements apply when authorized-lab testing is selected.

  3. Map requirements to firmware

    Responsible Cortex One

    SuperAgent Cortex One maps ioXt requirements to firmware/configuration locations, identifies evidence gaps, and proposes remediation priority per product profile.

  4. Collect baseline evidence

    Responsible Cortex One

    Export firmware builds, configuration manifests, and run entitled validation tests. Mark freshness against current lab assessment window.

  5. Implement fixes

    Responsible Cortex One

    Agent and/or professional delivery implements tested changes. Each change linked to ioXt requirement ID, product profile, and firmware version.

  6. Validate and re-test

    Responsible Cortex One

    Re-run validation tests on remediated firmware/configuration. Collect validation results and update evidence freshness to 'fresh' status.

  7. Prepare lab evidence package

    Responsible Professional specialist

    Assemble the evidence bundle for the agreed testing route, with requirement mapping, change/test links and submission checklist. The customer reviews and accepts it separately from program approval.

  8. Customer review

    Responsible Customer

    The customer accepts the prepared evidence package. Testing and program submission are separate steps under the selected route; the ioXt Alliance reviews submissions and approves certification when program criteria are met.

Delivery details

Repository and environment access

Repositories

  • Firmware source code for requirement mapping and remediationWrite access
  • Configuration manifests and device specifications for evidenceRead access
  • Test and validation pipelines for automated evidence generationWrite access

Environments

  • Developmentdevelopment · write access
  • Testtest · write access

Tools and entitlement

Entitled tools

No tools are pre-entitled.

Eligible tools

Eligibility depends on scope, licenses, and target approval.

  • firmware-validator validatorAvailable for ioXt scope; subject to actual scope, licenses, and target approval
  • config-analyzer analyzerAvailable for ioXt scope; subject to actual scope, licenses, and target approval
  • test-runner scannerAvailable for ioXt scope; subject to actual scope, licenses, and target approval
  • specialized-ioxt-validator validatorAvailable when authorized lab provides specific validation criteria

Provider requirements

Minimum experience
Familiarity with ioXt Alliance certification program, connected device security requirements, and authorized lab assessment process

The ioXt Alliance retains certification approval. Authorized labs perform testing when that route is selected; hardware/lab charges are separate. Eregis supplies remediation and evidence support, does not hold ioXt accreditation and does not issue certificates. Complex firmware changes may require professional delivery.

Evidence and acceptance

Evidence types

  • requirement-map
  • firmware-exports
  • config-manifests
  • test-results
  • traceability-links
  • submission-package
  • freshness-report
  • acceptance-checklist

Acceptance criteria

  • All applicable ioXt requirements for the product profile mapped to firmware/configuration locations with evidence statusVerified by Customer
  • Firmware evidence and validation results marked 'fresh' (within current assessment window) for all in-scope requirementsVerified by Customer
  • Every remediation change has passing validation tests linked to the originating ioXt requirement ID and firmware versionVerified by Agent
  • Lab evidence bundle contains requirement map, evidence chain, freshness report, and submission checklistVerified by Professional
  • The customer accepts the completeness and usability of the prepared evidence bundle for the agreed route. Any selected lab review, program submission and certification approval remain separate steps.Verified by Customer

Evidence freshness

Maximum age: 30 days.

Revalidation Assessment window change, new firmware deployment, or lab request for updated evidence

Current status

Intake
Scope review required

Confirm product profile, firmware/specification version and the applicable testing route before scoping. Authorized-lab work and hardware are arranged only where selected. Scope review remains required until estimation is calibrated.

Scoping
Scope review required

Calibration: Scope review required

Estimator calibration pending Cortex One benchmark on ioXt remediation patterns. Shows 'Scope review required' until calibrated.

Delivery
Not started

Evidence freshness: Freshness not yet determined

No active delivery for this service record

Tool eligibility
Status unknown

Tool eligibility subject to actual scope, licenses, and target approval. No purchased entitlement, running assessment, delivery, or certification claimed.

Fees

Assessment and provider fees
Program fees, agreed testing, hardware charges, inclusions and retest cycles are defined by the separately accepted provider engagement and paid to the contracted provider. Certification approval depends on program criteria and Alliance review; it is not purchased with this service.
Eregis agent credits
Eregis SuperAgent Cortex One execution credits for agent-only remediation work within scoped repositories. Credits fund agent execution time only.
Professional services
Vetted professional delivery for complex firmware findings, architectural changes, or product-specific requirements. Separately quoted and accepted per supplier agreement.
Tool licenses
External validation/test tool licenses where not covered by entitled tools. Customer retains tool entitlement decisions. Lab hardware/test charges are separate.

Program/testing fees, Eregis credits, professional services and tool licenses are separately authorized. Credits do not purchase certification or authorize submission. Authorized labs provide testing when selected; the ioXt Alliance retains certification approval.

Three conceptual panels: product scope, firmware remediation and evidence for the agreed ioXt testing route. Certification approval remains separate.

Who this service is for

Product engineering leads: Coordinate ioXt requirement-to-firmware mapping and track lab readiness across device variants

Security teams: Organize control evidence, manage authorized lab communication, and prepare submission materials

Compliance owners: Track progress toward ioXt certification with auditable evidence trails for each product profile

Assessment stages covered

Requirement mapping: Map ioXt program requirements to your product, profile and firmware version, identifying evidence gaps and remediation scope per the applicable ioXt specification version

Evidence preparation: Collect firmware/configuration exports, test results, and control documentation aligned to ioXt requirement IDs

Firmware/configuration remediation: Implement tested fixes for findings with SuperAgent Cortex One and vetted professionals; link changes to ioXt requirement IDs and product profile

Assessment evidence package: Prepare the evidence bundle and submission checklist for the agreed testing route, including lab-specific material when authorized-lab testing is selected.

Assistance modes

Agent-only: SuperAgent Cortex One executes scoped, repeatable remediation tasks

Agent + professional: SuperAgent Cortex One plus vetted specialists for complex findings

Frequently asked questions

What ioXt version does this support?

The applicable specification for your recorded product profile and firmware version. Confirm the assessment version and permitted testing route through the ioXt program and, where selected, the authorized lab; updates do not silently change an agreed engagement.

Can agent-only mode handle my ioXt assessment?

Agent-only mode works for well-defined, repeatable remediation tasks (e.g., configuration fixes, dependency updates, standard firmware patterns). Complex firmware architectural changes, product-specific requirements, and findings requiring specialized embedded security expertise need professional involvement.

What repository access is required?

Scoped read/write access to repositories containing the firmware source code and configuration. Optional read access to device specifications. You control expiry and can revoke at any time. No tokens exposed in the UI. Write access is required only where agreed remediation changes firmware/configuration or validates those changes.

How are fees separated?

ioXt program/lab fees (paid to ioXt Alliance/authorized lab), Eregis agent credits (SuperAgent execution), professional services (separately quoted), and external tool licenses (where required). Lab hardware/test charges are separate. Each is independently authorized.

What tools are entitled?

No tools are pre-entitled. Firmware validation, configuration analysis, and automated testing are eligible for ioXt work subject to actual scope, licenses, and target approval. Specialized validators require authorized lab criteria.

Who performs the ioXt certification?

The program offers self-certification or authorized-lab testing as applicable to the product/profile. The ioXt Alliance reviews submissions and approves certification when its criteria are met. Eregis prepares implementation and evidence; it does not issue certificates or control approval.

How is evidence freshness tracked?

Each evidence item has a freshness status: fresh (validated within current 30-day assessment window), stale (older than window), expired (window closed), or unknown (not yet determined). Revalidation triggers on assessment window change, new firmware deployment, or lab request.

What if credits run out during remediation?

Work pauses with clear notification. Partially completed work remains visible with its evidence chain. You can purchase additional credits or adjust scope.

Can I cancel professional engagement?

Yes, per the supplier agreement. Completed work up to cancellation is delivered with its evidence chain.

What happens if the lab requests changes?

Changes are tracked as new findings with their own evidence chain (finding key to proposed change to test to evidence). You review and accept before resubmission to the authorized lab.

Sources and references

ioXt Certifying Your Device (ioXt Alliance): Official program overview, certification process, and product profile requirements —https://ioxt.com/certifying-your-device

ioXt Content and Resources (ioXt Alliance): Program documentation, resources, and reference materials —https://ioxt.com/content-and-resources

ioXt Terms and Conditions (ioXt Alliance): Website-use terms only; this page does not establish certification-program participation terms or permission to use official marks. —https://ioxt.com/terms-and-conditions